CHARGOMATIC C1-300

  • Battery charger
  • Electric power supply
  • Primarily synchronized
  • Chassis
12 V 5 A
24 V 3 A
24 V 5 A


Description



Mechanical design
The chargers of the C1-300 series are mounted on an aluminum L-angle which can be fixed with three screws on a heat conductive surface.

Certification and CE marking.
The devices meet the basic requirements of the law relating to electromagnetic compatibility (89/336/EEC EEC Treaty), if they are operated in a closed steel housing.

Features

  • Input voltage range for 12 V 5 A and 24 V 3 A, 85-265 V AC
  • Over voltage protection at 2.7 V / cell from 1997

Data

Technical data

Device type C1–312–5 C1–324–3 C1–324–5
Rated voltage DC 12 V 24 V 24 V
Nominal output current 5 A 3 A 5 A
Nominal output current 13,8 V 27,6 V 27,6 V
Current limit 5 - 5,2 A 3 - 3,1 A 5 - 5,2 A
Short circuit current < 5 A < 3 A < 5 A
Back current at mains failure. ca < 4 mA < 4 mA < 4 mA
IU characteristic IU
"Hick up mode" < 7 V < 12 V < 12 V
Line voltage AC, 50/60 Hz 115 V/230 V
± 15%
115 V/230 V
± 15%
115 V/230 V
± 15%
Input current at 230 V 660 mA 740 mA 1,2 A
Switching frequency 40 kHz
Efficiency 0,80 0,81 0,82
Power factor 0,57 0,60 0,63
Ambient temperature range* 0º C/+45º C 0º C/+55º C 0º C/+40º C
Spikes about 0.3%** 0,5% pp 0,3% pp 0,3% pp
Output voltage ripple 0,2% pp 0,1% pp 0,1% pp
Accuracy of the output voltage between 86-265 V < 0,02% < 0,02% < 0,02%
Load regulation 1% 0,5% 0,5%
Cooling Convection cooling, aluminum profiles
Cross section max. 4 mm²
Dimensions (L x B x H) I/VDE 0805160 x 104 x 40 mm


*0,15 m² provided mounting plate; without mounting plate max. ambient temperature +40 º C
**measured directly at the terminal block
Dial Engineering AG · Langfeldstrasse 96 · CH-8500 Frauenfeld · Tel. +41 52 723 0575 · Fax +41 52 723 0576 · info@dial-eng.ch

A TreeCone Group Company · www.TreeCone.ch